Medical Equipment Calibration is the process of configuring the measurement and the accuracy of the medical device or the medical system used in Hospitals. This field intends to offer advance healthcare treatment, including diagnosis, monitoring and therapy.

The medical calibration measurements, is important because they establish whether the medical devices are appropriate, according to the international standards or not. The calibration also helps to minimise misdiagnosis caused by poorly calibrated machine. It is very important to configure hospital systems, according to the standard calibration because these machines need to be absolutely accurate since it is a matter of life and death.

group_work View our Offerings

     

    Offerings

    Technical Specification

    Description

    BP Apparatus

    All Ranges

    Manometer and Leak test

    Defibrillator Calibration

    Calibration of all ranges

    Energy, ECG, Charging time and Electrical safety

    ECG Machines Calibration

    Calibration of all ranges

    HV testing, Leakage Current test, Earth Bond, Resistance

    Electrosurgical Diathermy (Cautery Machines) Calibration

    Calibration of all ranges

    Electrical safety test, ESU output Power, Current, Peak to peak voltage, crest factor

    Fetal Monitor Calibration

    Calibration of all ranges

    Electrical safety and IUP

    Hemotherm Calibration

    Calibration of all ranges

    Temperature Calibration

    Incubator Analyzer Calibration

    Humidity: 30 to 90 %RH
     Sound Level: 94 dB
     Temperature: 10 to 50 °C

    Calibration of Fluke INCU-2
     Calibration parameters Pressure, Flow rate, TIME, Temperature, RH, Airflow

    Infusion Pump Analyzer Calibration

    Flow Rate: 10 ml/hr. to 1000 ml/hr.
     Flow Volume: 5 ml to 400 ml

    Calibration of Fluke IDA1-S,
    IDA4, IDA5, IDA4 Plus,
    IDA5
     Calibration parameters: Flow rate, Flow Volume, Pressure

    NIBP Analyzer Calibration

    pressure: 0 to 500mmHg

    Calibration parameters: Pressure, leak rate

    O T Lamp, Light Sources Calibration

    Calibration of all ranges

    Lux Measurement

    O2 Analyzer Calibration

    21% and 100% of O2

    Calibration of Fluke Max O2

    Pacemaker Analyzer Calibration

    Resistance: 0 to 1500ohm

    Calibration of Fluke Sigmapace1000
     Calibration parameters: Voltage, Resistance, Current
     

    Pacemaker Calibration

    Calibration of all ranges

     Demand and asynchronous Mode

    Patient Monitors Calibration

    Calibration of all ranges

    ECG, Spo2, NIBP, respiration, Electrical safety

    Phototherapy Calibration

    Calibration of all ranges

    Temperature Calibration, Electrical safety

    Physiotherapy Equipment Calibration

    Calibration of all ranges

    Electrical safety

    Pulse Oximeters Calibration

    Calibration of all ranges

    Spo2, Electrical safety

    SPo2 Functional Tester Calibration

    SPO2: 30 to 100%

    Calibration of Fluke Index 2
     

    Spo2 Verification

    SPO2: 30 to 100%

    Oxygen Saturation verification

    Syringe Pumps and Infusion Pumps Calibration

    Calibration of all ranges

    Flow, Occlusion, PCA Bolus, Volume, Electrical safety Test

    Tourniquets Calibration

    Calibration of all ranges

    Pressure calibration

    Ventilator Calibration and Anesthesia Machine Calibration

    Calibration of all ranges

    Electrical safety and 21 Ventilator Parameter like Tidal volume, I: E Ratio, Rate, PEEP etc.

    Warmers and Patient Incubators Calibration

    Calibration of all ranges

    Temperature Calibration

Featured

Capturing real-time data helps us get more uninterrupted output

These days, smart would mean a device connected to a network, unlike standalone devices. Through this connectivity, a great deal of data generated during the device’s operation is transmitted to other devices, when interpreted manually or digitally, gives information, and if acted upon, can yield substantial, tangible benefits.

Who is the greenest of them all?

Visit Hubble at Plant 13 Annex for a meal or a meeting and discover what sustainability means to Godrej & Boyce.

A smart way of managing productive resources

A transformative change significantly alters the profile, capabilities, contours and culture of an organization. Total Productive Maintenance (TPM) is a well-established way of managing production resources for meeting ever-rising standards of productivity, quality and reliability.

Godrej Bambusa Bikes

In 2012, Mr. Vijay Crishna visited Antarctica with British explorer, Sir Robert Swan, to witness climate change, first-hand. During the visit, their group welcomed two young Dutch men who had spent the previous 15 months cycling 16,000 kms from Deadhorse, Alaska to Ushuaia, riding bamboo-framed bikes! Mr. Crishna was very impressed with the bikes, and on his return, he asked the Lawkim team to develop such bikes.

“The essence of strategy is also choosing what not to do!”

Talk of growth, and what comes naturally to mind is: widening of the product offerings, adding new categories, expanding into newer markets, forming strategic alliances and so on.

The case of the Pinaka Rocket Assembly Line.

Automation is highly desirable to execute well when production lines are complex and there is an excessive dependency on manual operations.

Sailing the Uncharted Seas

The ‘can-do’ attitude and deep confidence in the capabilities of the team are essential to execute large projects having complex developmental work.

Capabilities
Quality Management

Read more

Assembly

Read more

Enquiry

Thank you for getting in touch!

compare Compare Now